High Set X-Nipples

About

In many basins, wells have been permitted to flow to surface up the casing prior to installation of tubing. This is especially common in high volume gas wells. Subsequently, operators snub tubing into the wellbore. These snubbing operations often require incorporation of profile nipples (X Nipples) into the tubing string. Ultimately, after such a snubbing operation, profile nipples may be set in the tubing string too high for effective plunger operations.

Jetted, Padded

Plungers

Our 2-3/8” AXL Double-Pad and 2-3/8” Jetted Double-Pad plungers have mandrels, collars, and shoulders smaller than 1.875” in diameter. Additionally, the pads will collapse down to smaller than a 1.875” diameter. This means that (in the right configuration) we can run a Double-Padded plunger through an X-Nipple. Our preference is to use the Jetted Double-Pad plunger to do so, as gas pressure from below the tool, will inflate the pads out to contact the tubing wall during plunger rise. This is especially important if the Bottom-Hole Assembly is set at inclinations over ~15°.

Bottom Hole

Assembly

In 2-3/8” tubing strings, an X-Nipple has an internal diameter of 1.875”. Several commonly used tools have smaller outside diameters than this measurement. Both “A” Stops (Tubing-Stops) and “F” Stops (Collar-Stops) will therefore fit through an X-Nipple. Additionally, when configured with a collet, our bottom-hole spring offerings will fit through the X-Nipple. We can therefore set a complete range of bottom hole assemblies on top of Tubing-Stops or Collar-Stops through an X-Nipple. A similar approach can also be employed in 2-7/8” tubing strings.

Ported

Plungers

Most solid-body plungers rely on close contact between the plunger and the tubing wall to minimize slippage past the plunger. Our ported tools (including Vipers and Venturi Vipers) rely instead on a turbulent gas seal between the plunger and the tubing wall. This means we can effectively operate ported tools with a much larger gap between the plunger and the tubing wall. For example, our 2-3/8” Vipers and Venturi Viper plungers are not considered worn out until, either the OD is less than 1.86” or the plunger no longer makes consistent arrivals. We have therefore proved successful in operating under-sized tools (1.870” OD Vipers and Venturi Vipers) in wells through high-set X-Nipples.​

For more information please contact us below or reach out to your Account Manager. To find your Account Manager, check out our Service Map.

For more information about how Well Master can meet your needs, contact us today!

  • Instagram
  • Facebook
  • LinkedIn
  • YouTube
  • TikTok
Return to Home Page

US Corporate Office

+1 (303) 980-0254

info@wellmaster.com

16201 Table Mountain Pkwy Suite 100

Golden, CO 80403

Canada Corporate Office

+1 (780) 539-5037

WMCanada@wellmaster.com

102,11334 89 Avenue

Grande Prairie, AB T8V 5V8

© 2024 Well Master Corporation. All rights reserved.

bottom of page